Fire Sprinkler System Wet Alarm Valve

  • Audited Supplier
  • 10 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Customizable Materials: Available in Ductile Iron, Cast Iron, or Stainless Steel.
  • Wide Size Range: Nominal diameters from 80mm to 250mm (3" to 10").
  • High Pressure Resistance: Working pressure 1.6MPa, strength test up to 6.4MPa.
  • OEM Logo Service: We can add your logo and design custom branding.
  • Low MOQ for Standard: Low minimum order quantity available for conventional products.
  • Fast Off-Season Delivery: Lead time within 15 workdays during off-peak seasons.
  • Global Sales Network: Exported to North America, Europe, Asia, and more.

Product Images of Fire Sprinkler System Wet Alarm Valve

Fire Sprinkler System Wet Alarm Valve
Fire Sprinkler System Wet Alarm Valve pictures & photos
Fire Sprinkler System Wet Alarm Valve
Fire Sprinkler System Wet Alarm Valve pictures & photos
Fire Sprinkler System Wet Alarm Valve
Fire Sprinkler System Wet Alarm Valve pictures & photos
Fire Sprinkler System Wet Alarm Valve
Fire Sprinkler System Wet Alarm Valve pictures & photos
Fire Sprinkler System Wet Alarm Valve
Fire Sprinkler System Wet Alarm Valve pictures & photos
Fire Sprinkler System Wet Alarm Valve
Fire Sprinkler System Wet Alarm Valve pictures & photos
Fire Sprinkler System Wet Alarm Valve
  • Fire Sprinkler System Wet Alarm Valve
  • Fire Sprinkler System Wet Alarm Valve
    Fire Sprinkler System Wet Alarm Valve
  • Fire Sprinkler System Wet Alarm Valve
    Fire Sprinkler System Wet Alarm Valve
  • Fire Sprinkler System Wet Alarm Valve
    Fire Sprinkler System Wet Alarm Valve
  • Fire Sprinkler System Wet Alarm Valve
    Fire Sprinkler System Wet Alarm Valve
  • Fire Sprinkler System Wet Alarm Valve
    Fire Sprinkler System Wet Alarm Valve
  • Fire Sprinkler System Wet Alarm Valve
    Fire Sprinkler System Wet Alarm Valve

Find Similar Products

Product Description

Fire sprinkler system wet alarm valve

Introduction:
ZSFZ Wet alarm valve is the key component of automatic sprinkler system. It consist of wet alarm valves, retard, water alarm, and other components (such as pressure switches, flow meters, closed head etc.). The system usually in standby state, the pressure pipe filled with water. When the fire starts and  environmental temperature rise, lead to the fire sprinkler sensitive element (glass ball) action, sealing components off, auto start the wet system, water directly sprayed into the fire area and send alarm signals to the control center. It's widely used in some fire danger places(4 ºC to 70ºC environment temperature), such as warehouse, hotel, mall, office or high building and garage etc.warehouses, hotels, shopping malls, hospitals, theaters, office buildings, high-rise building and garage.

Technical parameters:
Model ZSFZ80 ZSFZ100 ZSFZ125 ZSFZ150 ZSFZ200 ZSFZ250
Norminial diameter(mm) 80 100 125 150 200 250
Working pressure(Mpa) 1.6Mpa
Sealed test(Mpa) 3.2Mpa
Strength test(Mpa) 6.4Mpa
Flow rate(L/min) 15<Q<60
Retard alarm time(s) 5~90
Friction resistance(Mpa) 0.035
Height of alarm valve(mm) 250 260 265 270 370 430
Outside diameter of flange(mm) 200 220 250 285 340 405
Inside diameter of flange screw hole(mm) 160 180 210 240 295 355
Diameter of screw hole(mm) 8 12
Quantity of screw hole 18 22 26

Wet alarm check valve structure
Fire Sprinkler System Wet Alarm Valve
Installation graphics
Fire Sprinkler System Wet Alarm Valve

Photos
Fire Sprinkler System Wet Alarm ValveFire Sprinkler System Wet Alarm ValveFire Sprinkler System Wet Alarm ValveFire Sprinkler System Wet Alarm ValveFire Sprinkler System Wet Alarm ValveFire Sprinkler System Wet Alarm Valve
Our Company
We could supply fire hose, fire hose fittings, spray nozzle, coupling, automatic fire sprinkler system products, gate valves, check valves, ball valves, etc. All these products strictly confirming to JIS, API ans BS standards. All of our products comply with international quality standards and are greatly appreciate in avariety of markets around world. Our factory is covering an area of 15900 square meters, we now over 300 workers. Our well-equipped facilities and excellent quality control throughout all stages of production enable us to guarteen total customer satisfaction. As a result of our high quality products and outstanding customer service, we have gained a globe sales network reaching the North America, South America, Mideast, Southeast Asia, East Europe, etc. 

Certificate
Fire Sprinkler System Wet Alarm Valve
Other Firefighting Equipment

Fire Sprinkler System Wet Alarm Valve

FAQ

1. Could you supply the samples?
Free samples always ready if the value is within our purview.

2.Do you have the MOQ?
For conventional products, Low MOQ.

3. Can you add some logo on the products?
Yes. We could OEM and design your logo.

4. Are you able to design or explore a new products for us?
Yes, we are able to, if the clients could supply the drawings or samples.

 

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR247369". Items marked "verified" are certified.

Watch Video
Watch Video
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED

About Our Factory & Business Background

Address
Fuxi Commercial and Business Building, Meilin Street, Quanzhou, Fujian, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DAT, FAS, DDP, DAP, CIP, CPT, Others, FCA
Average Lead Time
Peak Season Lead Time: 1-3 months
Off Season Lead Time: within 15 workdays
Nearest Port
Xiamen, Ningbo, Guangzhou

Our Production Capability & Technical Expertise

Main Products
Fire Hose, Fire Hose Pipe, Water Delivery Hose/Agricultural Hose, Fire Sprinkler Head, Alarm Check Valve, Fire Hydrant, Fire Water Monitor/Water Cannon, Fire Fighting Equipment, Fire Fighting Spray Nozzle, Foam Bladder Tank

Our Industry Experience & Global Business Record

Export Year
2011-03-09
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

Can you provide free samples?
Free samples are always ready if the value is within our purview.
What is the Minimum Order Quantity (MOQ)?
For conventional products, we offer a low MOQ.
Can you add a logo to the products?
Yes, we can provide OEM services and design your logo.
Do you support custom product design?
Yes, we can design or explore new products if clients supply drawings or samples.
What materials are available for the valve?
The valve is customizable in Ductile Iron, Cast Iron, or Stainless Steel.
What is the working pressure of the valve?
The standard working pressure is 1.6MPa, with a strength test of 6.4MPa.
What are the available sizes?
Sizes range from 80mm to 250mm (3" to 10").
What is the lead time for orders?
Peak season lead time is 1-3 months; off-season is within 15 workdays.