2 Wire Conventional Optical Smoke Detector for Fire Alarm System

  • Audited Supplier
  • 10 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Images of 2 Wire Conventional Optical Smoke Detector for Fire Alarm System

2 Wire Conventional Optical Smoke Detector for Fire Alarm System
2 Wire Conventional Optical Smoke Detector for Fire Alarm System pictures & photos
2 Wire Conventional Optical Smoke Detector for Fire Alarm System
2 Wire Conventional Optical Smoke Detector for Fire Alarm System pictures & photos
2 Wire Conventional Optical Smoke Detector for Fire Alarm System
2 Wire Conventional Optical Smoke Detector for Fire Alarm System pictures & photos
2 Wire Conventional Optical Smoke Detector for Fire Alarm System
2 Wire Conventional Optical Smoke Detector for Fire Alarm System pictures & photos
2 Wire Conventional Optical Smoke Detector for Fire Alarm System
2 Wire Conventional Optical Smoke Detector for Fire Alarm System pictures & photos
2 Wire Conventional Optical Smoke Detector for Fire Alarm System
2 Wire Conventional Optical Smoke Detector for Fire Alarm System pictures & photos
2 Wire Conventional Optical Smoke Detector for Fire Alarm System
  • 2 Wire Conventional Optical Smoke Detector for Fire Alarm System
  • 2 Wire Conventional Optical Smoke Detector for Fire Alarm System
    2 Wire Conventional Optical Smoke Detector for Fire Alarm System
  • 2 Wire Conventional Optical Smoke Detector for Fire Alarm System
    2 Wire Conventional Optical Smoke Detector for Fire Alarm System
  • 2 Wire Conventional Optical Smoke Detector for Fire Alarm System
    2 Wire Conventional Optical Smoke Detector for Fire Alarm System
  • 2 Wire Conventional Optical Smoke Detector for Fire Alarm System
    2 Wire Conventional Optical Smoke Detector for Fire Alarm System
  • 2 Wire Conventional Optical Smoke Detector for Fire Alarm System
    2 Wire Conventional Optical Smoke Detector for Fire Alarm System
  • 2 Wire Conventional Optical Smoke Detector for Fire Alarm System
    2 Wire Conventional Optical Smoke Detector for Fire Alarm System

Find Similar Products

Product Description

2 Wire Conventional Optical Smoke Detector for Fire Alarm System

Introduction
The detectors are photoelectric detector which use a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.
Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.
The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel.
Heat detector and smoke & heat detector combine a photo electronic sensing chamber and a temperature heat detector.


Specification
Operating Voltage Range 9 to 28 VDC Volts Non-polarized
Standby Current ≤120μA@24VDC
Maximum Alarm Current (LED on) ≤15mA@24VDC
(1K Ohm current-limiting resistance)
Operating Humidity Range ≤95%RH(40°C±2°C) Relative Humidity, Non-condensing
Operating Temperature Range -10°C to 50°C (14°F to 122°F)
Smoke Alarm Sensitivity 1.06±.26%FT
Fix temperature Alarm 57°C (135°F) A1R
Rate of rise Alarm 7.1°C/5S A1R
Height 48.2 mm installed in Base
Diameter 99.45 mm

Photoes
2 Wire Conventional Optical Smoke Detector for Fire Alarm System
2 Wire Conventional Optical Smoke Detector for Fire Alarm System
2 Wire Conventional Optical Smoke Detector for Fire Alarm System
2 Wire Conventional Optical Smoke Detector for Fire Alarm System
2 Wire Conventional Optical Smoke Detector for Fire Alarm System2 Wire Conventional Optical Smoke Detector for Fire Alarm System2 Wire Conventional Optical Smoke Detector for Fire Alarm System

Package&Shipping
2 Wire Conventional Optical Smoke Detector for Fire Alarm System2 Wire Conventional Optical Smoke Detector for Fire Alarm System
Other Products Recommendation
2 Wire Conventional Optical Smoke Detector for Fire Alarm System

Our Company
We could supply fire hose, fire hose fittings, spray nozzle, coupling, automatic fire sprinkler system products, gate valves, check valves, ball valves, etc. All these products strictly confirming to JIS, API ans BS standards. All of our products comply with international quality standards and are greatly appreciate in avariety of markets around world. Our factory is covering an area of 15900 square meters, we now over 300 workers. Our well-equipped facilities and excellent quality control throughout all stages of production enable us to guarteen total customer satisfaction. As a result of our high quality products and outstanding customer service, we have gained a globe sales network reaching the North America, South America, Mideast, Southeast Asia, East Europe, etc. 

Certificate
2 Wire Conventional Optical Smoke Detector for Fire Alarm System
FAQ

1. Could you supply the samples?

Free samples always ready if the value is within our purview.

2.Do you have the MOQ?
For conventional products, Low MOQ.

3. Can you add some logo on the products?
Yes. We could OEM and design your logo.

4. Are you able to design or explore a new products for us?
Yes, we are able to, if the clients could supply the drawings or samples.

 

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR247369". Items marked "verified" are certified.

Watch Video
Watch Video
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED

About Our Factory & Business Background

Address
Fuxi Commercial and Business Building, Meilin Street, Quanzhou, Fujian, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DAT, FAS, DDP, DAP, CIP, CPT, Others, FCA
Average Lead Time
Peak Season Lead Time: 1-3 months
Off Season Lead Time: within 15 workdays
Nearest Port
Xiamen, Ningbo, Guangzhou

Our Production Capability & Technical Expertise

Main Products
Fire Hose, Fire Hose Pipe, Water Delivery Hose/Agricultural Hose, Fire Sprinkler Head, Alarm Check Valve, Fire Hydrant, Fire Water Monitor/Water Cannon, Fire Fighting Equipment, Fire Fighting Spray Nozzle, Foam Bladder Tank

Our Industry Experience & Global Business Record

Export Year
2011-03-09
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now