Fire Detection Equipment 2 Wire Conventional Beam Smoke Detector

Product Details
Customization: Available
Type: Smoke Detectors
Anti-theft Alarm System Approach: Active
Still deciding? Get samples of US$ 6/Piece
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 30 days
100% Finished Products Inspection
The supplier inspects 100% of finished products.
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (8)
  • Fire Detection Equipment 2 Wire Conventional Beam Smoke Detector
  • Fire Detection Equipment 2 Wire Conventional Beam Smoke Detector
  • Fire Detection Equipment 2 Wire Conventional Beam Smoke Detector
  • Fire Detection Equipment 2 Wire Conventional Beam Smoke Detector
  • Fire Detection Equipment 2 Wire Conventional Beam Smoke Detector
  • Fire Detection Equipment 2 Wire Conventional Beam Smoke Detector
Find Similar Products

Basic Info.

Model NO.
CSD004
Anti-Theft Alarm System Type
Smoke Alarms
Anti-Theft Alarm System-Wide
Point Control Alarm Detectors
Anti-Theft Alarm System Distance
Power Detector
Types of Smoke Detectors
Photoelectric Smoke Style
Voltage
24V
Wire
2 Wires
Certificate
Ce/ISO
Transport Package
Standard Export Package
Trademark
OEM
Origin
Fujian
HS Code
8531100000
Production Capacity
10000pieces/Month

Product Description

Fire Detection Equipment 2 Wire Conventional Beam Smoke Detector

Introduction
The detectors are photoelectric detector which use a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.
Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.
The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel.
Heat detector and smoke & heat detector combine a photo electronic sensing chamber and a temperature heat detector.


Specification
Operating Voltage Range 9 to 28 VDC Volts Non-polarized
Standby Current ≤120μA@24VDC
Maximum Alarm Current (LED on) ≤15mA@24VDC
(1K Ohm current-limiting resistance)
Operating Humidity Range ≤95%RH(40°C±2°C) Relative Humidity, Non-condensing
Operating Temperature Range -10°C to 50°C (14°F to 122°F)
Smoke Alarm Sensitivity 1.06±.26%FT
Fix temperature Alarm 57°C (135°F) A1R
Rate of rise Alarm 7.1°C/5S A1R
Height 48.2 mm installed in Base
Diameter 99.45 mm

Photoes
Fire Detection Equipment 2 Wire Conventional Beam Smoke DetectorFire Detection Equipment 2 Wire Conventional Beam Smoke DetectorFire Detection Equipment 2 Wire Conventional Beam Smoke DetectorFire Detection Equipment 2 Wire Conventional Beam Smoke DetectorFire Detection Equipment 2 Wire Conventional Beam Smoke DetectorFire Detection Equipment 2 Wire Conventional Beam Smoke DetectorFire Detection Equipment 2 Wire Conventional Beam Smoke DetectorFire Detection Equipment 2 Wire Conventional Beam Smoke DetectorFire Detection Equipment 2 Wire Conventional Beam Smoke Detector