• Fire Detection Equipment 2 Wire Conventional Beam Smoke Detector
  • Fire Detection Equipment 2 Wire Conventional Beam Smoke Detector
  • Fire Detection Equipment 2 Wire Conventional Beam Smoke Detector
  • Fire Detection Equipment 2 Wire Conventional Beam Smoke Detector
  • Fire Detection Equipment 2 Wire Conventional Beam Smoke Detector
  • Fire Detection Equipment 2 Wire Conventional Beam Smoke Detector

Fire Detection Equipment 2 Wire Conventional Beam Smoke Detector

Type: Smoke Detectors
Anti-theft Alarm System Approach: Active
Anti-Theft Alarm System Type: Smoke Alarms
Anti-Theft Alarm System-Wide: Point Control Alarm Detectors
Anti-Theft Alarm System Distance: Power Detector
Types of Smoke Detectors: Photoelectric Smoke Style
Samples:
US$ 6/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
CSD004
Voltage
24V
Wire
2 Wires
Certificate
Ce/ISO
Transport Package
Standard Export Package
Trademark
OEM
Origin
Fujian
HS Code
8531100000
Production Capacity
10000pieces/Month

Product Description

Fire Detection Equipment 2 Wire Conventional Beam Smoke Detector

Introduction
The detectors are photoelectric detector which use a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.
Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.
The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel.
Heat detector and smoke & heat detector combine a photo electronic sensing chamber and a temperature heat detector.


Specification
Operating Voltage Range 9 to 28 VDC Volts Non-polarized
Standby Current ≤120μA@24VDC
Maximum Alarm Current (LED on) ≤15mA@24VDC
(1K Ohm current-limiting resistance)
Operating Humidity Range ≤95%RH(40°C±2°C) Relative Humidity, Non-condensing
Operating Temperature Range -10°C to 50°C (14°F to 122°F)
Smoke Alarm Sensitivity 1.06±.26%FT
Fix temperature Alarm 57°C (135°F) A1R
Rate of rise Alarm 7.1°C/5S A1R
Height 48.2 mm installed in Base
Diameter 99.45 mm

Photoes
Fire Detection Equipment 2 Wire Conventional Beam Smoke DetectorFire Detection Equipment 2 Wire Conventional Beam Smoke DetectorFire Detection Equipment 2 Wire Conventional Beam Smoke DetectorFire Detection Equipment 2 Wire Conventional Beam Smoke DetectorFire Detection Equipment 2 Wire Conventional Beam Smoke DetectorFire Detection Equipment 2 Wire Conventional Beam Smoke DetectorFire Detection Equipment 2 Wire Conventional Beam Smoke DetectorFire Detection Equipment 2 Wire Conventional Beam Smoke DetectorFire Detection Equipment 2 Wire Conventional Beam Smoke Detector
Other Products Recommendation

Fire Detection Equipment 2 Wire Conventional Beam Smoke Detector
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, ISO 14064, GMP, BSCI, BS 25999-2, ISO 13485, ANSI/ESD, ISO 29001, ISO 50001, PAS 28000, ISO 10012, ISO 17025
OEM/ODM Availability
Yes