Fire Alarm Check Valve for Automatic Fire Sprinkler Fire Protection System

Product Details
Customization: Available
Sprinkler Head Type: Closed
Alarm Valve Type: Wet Alarm Valve
Still deciding? Get samples of US$ 50/set
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 30 days
100% Finished Products Inspection
The supplier inspects 100% of finished products.
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (8)
  • Fire Alarm Check Valve for Automatic Fire Sprinkler Fire Protection System
  • Fire Alarm Check Valve for Automatic Fire Sprinkler Fire Protection System
  • Fire Alarm Check Valve for Automatic Fire Sprinkler Fire Protection System
  • Fire Alarm Check Valve for Automatic Fire Sprinkler Fire Protection System
  • Fire Alarm Check Valve for Automatic Fire Sprinkler Fire Protection System
  • Fire Alarm Check Valve for Automatic Fire Sprinkler Fire Protection System
Find Similar Products

Basic Info.

Model NO.
ZSFZ
Automatically Opened and Closed Repeatedly
Can′t Automatically Opened and Closed
Closed Fire Sprinkler System
Wet Fire Sprinkler System
Wet Alarm Valve Structure
Seat Type
Alarm Valve Diameter
80mm-250mm
Finished
Red Painting
Size
3"/4"/5"/6"/8"/10"
Working Pressure
1.6MPa
Connection
Flange
Accessories
Retard Chamber, Water Motor Gong, etc.
Transport Package
Standard Export Package
Specification
3"-10"
Trademark
SINCO/OEM
Origin
Quanzhou, Fujian
HS Code
8481804090
Production Capacity
5000 Sets/Month

Product Description

Fire Alarm Check Valve for Automatic Fire Sprinkler Fire Protection System

Introduction
Alarm Check Valve is core element in wet pipe fire sprinkler systems. It serves a dual purpose which prevents a reverse flow of water (non-return), also provides for the use of the water motor gong. Meanwhile, in the event of variable pressure condition, false alarm is prevented with provision of retard chamber at the external bypass.

Feature
Standard: ANSI/ BS/ GB
Connection: Flanged as ANSI B16.1/ EN 1092-2
Installation: Vertical
Test: Factory hydro test 350 psi (2.4 MPa)
Temperature: 4°C to 70°C
W. pressure: 175/ 300 psi (1.21/ 2.07 MPa)
Surface: FBE coating as AWWA C550

Main Parts
Body Ductile Iron Cover Ductile iron
Disc Ductile iron / brass + EPDM Stem SS304/galvanized pipe
Seat Bronze/Cast iron Accessories Standard trim & accessories, Retard chamber,
Alarm pressure switch, Water motor gong, etc.

Technical parameters:
Model ZSFZ80 ZSFZ100 ZSFZ125 ZSFZ150 ZSFZ200 ZSFZ250
Norminial diameter(mm) 80 100 125 150 200 250
Working pressure(Mpa) 1.6Mpa
Sealed test(Mpa) 3.2Mpa
Strength test(Mpa) 6.4Mpa
Flow rate(L/min) 15<Q<60
Retard alarm time(s) 5~90
Friction resistance(Mpa) ≤0.035
Height of alarm valve(mm) 250 260 265 270 370 430
Outside diameter of flange(mm) 200 220 250 285 340 405
Inside diameter of flange screw hole(mm) 160 180 210 240 295 355
Diameter of screw hole(mm) 8 12
Quantity of screw hole 18 22 26

Wet alarm check valve structure
Fire Alarm Check Valve for Automatic Fire Sprinkler Fire Protection System
Fire Alarm Check Valve for Automatic Fire Sprinkler Fire Protection SystemFire Alarm Check Valve for Automatic Fire Sprinkler Fire Protection SystemFire Alarm Check Valve for Automatic Fire Sprinkler Fire Protection SystemFire Alarm Check Valve for Automatic Fire Sprinkler Fire Protection SystemFire Alarm Check Valve for Automatic Fire Sprinkler Fire Protection SystemFire Alarm Check Valve for Automatic Fire Sprinkler Fire Protection System
Our Company

We could supply fire hose, fire hose fittings, spray nozzle, coupling, automatic fire sprinkler system products, gate valves, check valves, ball valves, etc. All these products strictly confirming to JIS, API ans BS standards. All of our products comply with international quality standards and are greatly appreciate in avariety of markets around world. Our factory is covering an area of 15900 square meters, we now over 300 workers. Our well-equipped facilities and excellent quality control throughout all stages of production enable us to guarteen total customer satisfaction. As a result of our high quality products and outstanding customer service, we have gained a globe sales network reaching the North America, South America, Mideast, Southeast Asia, East Europe, etc. 
Fire Alarm Check Valve for Automatic Fire Sprinkler Fire Protection System
Fire Alarm Check Valve for Automatic Fire Sprinkler Fire Protection System

Other Firefighting EquipmentFire Alarm Check Valve for Automatic Fire Sprinkler Fire Protection System

FAQ
1. Could you supply the samples?

Free samples always ready if the value is within our purview.

2.Do you have the MOQ?
For conventional products, Low MOQ.

3. Can you add some logo on the products?
Yes. We could OEM and design your logo.

4. Are you able to design or explore a new products for us?
Yes, we are able to, if the clients could supply the drawings or samples.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier