Cast Iron Alarm Valve Pn16 Alarm Check Valve
|
Still deciding? Get samples of $ !
Request Sample
|
Product Details
| Customization: | Available |
|---|---|
| Material: | Ductile Iron/Cast Iron/Stainless Steel |
| Finished: | Red Painting |
Diamond Member Since 2017
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
High Repeat Buyers Choice
Fast Delivery
100% Finished Products Inspection
R&D Capabilities
More than 50% of buyers repeatedly choose the supplier
The supplier can deliver the goods within 30 days
The supplier inspects 100% of finished products.
The supplier has 1 R&D engineers, you can check the Audit Report for more information
Sign In to see all verified strength labels (8)
Find Similar Products
Basic Info.
- Model NO.
- ZSFZ80-ZSFZ250
- Size
- 3"/4"/5"/6"/8"/10"
- Working Pressure
- 1.6MPa
- Connection
- Flange
- Accessories
- Retard Chamber, Water Motor Gong, etc.
- Transport Package
- Standard Export Package
- Specification
- 3"-10"
- Trademark
- SINCO/OEM
- Origin
- Quanzhou, Fujian
- HS Code
- 84818
- Production Capacity
- 5000 Sets/Month
Product Description
Cast Iron alarm valve Pn16 Alarm Check Valve
Introduction:
ZSFZ Wet alarm valve is the key component of automatic sprinkler system. It consist of wet alarm valves, retard, water alarm, and other components (such as pressure switches, flow meters, closed head etc.). The system usually in standby state, the pressure pipe filled with water. When the fire starts and environmental temperature rise, lead to the fire sprinkler sensitive element (glass ball) action, sealing components off, auto start the wet system, water directly sprayed into the fire area and send alarm signals to the control center. It's widely used in some fire danger places(4 ºC to 70ºC environment temperature), such as warehouse, hotel, mall, office or high building and garage etc.warehouses, hotels, shopping malls, hospitals, theaters, office buildings, high-rise building and garage.
Technical parameters:
Wet alarm check valve structure
Installation graphics
Photos






Our Company
We could supply fire hose, fire hose fittings, spray nozzle, coupling, automatic fire sprinkler system products, gate valves, check valves, ball valves, etc. All these products strictly confirming to JIS, API ans BS standards. All of our products comply with international quality standards and are greatly appreciate in avariety of markets around world. Our factory is covering an area of 15900 square meters, we now over 300 workers. Our well-equipped facilities and excellent quality control throughout all stages of production enable us to guarteen total customer satisfaction. As a result of our high quality products and outstanding customer service, we have gained a globe sales network reaching the North America, South America, Mideast, Southeast Asia, East Europe, etc.
Certificate

Other Firefighting Equipment
FAQ
1. Could you supply the samples?
Free samples always ready if the value is within our purview.
Introduction:
ZSFZ Wet alarm valve is the key component of automatic sprinkler system. It consist of wet alarm valves, retard, water alarm, and other components (such as pressure switches, flow meters, closed head etc.). The system usually in standby state, the pressure pipe filled with water. When the fire starts and environmental temperature rise, lead to the fire sprinkler sensitive element (glass ball) action, sealing components off, auto start the wet system, water directly sprayed into the fire area and send alarm signals to the control center. It's widely used in some fire danger places(4 ºC to 70ºC environment temperature), such as warehouse, hotel, mall, office or high building and garage etc.warehouses, hotels, shopping malls, hospitals, theaters, office buildings, high-rise building and garage.
Technical parameters:
| Model | ZSFZ80 | ZSFZ100 | ZSFZ125 | ZSFZ150 | ZSFZ200 | ZSFZ250 |
| Norminial diameter(mm) | 80 | 100 | 125 | 150 | 200 | 250 |
| Working pressure(Mpa) | 1.6Mpa | |||||
| Sealed test(Mpa) | 3.2Mpa | |||||
| Strength test(Mpa) | 6.4Mpa | |||||
| Flow rate(L/min) | 15<Q<60 | |||||
| Retard alarm time(s) | 5~90 | |||||
| Friction resistance(Mpa) | ≤0.035 | |||||
| Height of alarm valve(mm) | 250 | 260 | 265 | 270 | 370 | 430 |
| Outside diameter of flange(mm) | 200 | 220 | 250 | 285 | 340 | 405 |
| Inside diameter of flange screw hole(mm) | 160 | 180 | 210 | 240 | 295 | 355 |
| Diameter of screw hole(mm) | 8 | 12 | ||||
| Quantity of screw hole | 18 | 22 | 26 | |||
Wet alarm check valve structure
Installation graphics
Photos






Our Company
We could supply fire hose, fire hose fittings, spray nozzle, coupling, automatic fire sprinkler system products, gate valves, check valves, ball valves, etc. All these products strictly confirming to JIS, API ans BS standards. All of our products comply with international quality standards and are greatly appreciate in avariety of markets around world. Our factory is covering an area of 15900 square meters, we now over 300 workers. Our well-equipped facilities and excellent quality control throughout all stages of production enable us to guarteen total customer satisfaction. As a result of our high quality products and outstanding customer service, we have gained a globe sales network reaching the North America, South America, Mideast, Southeast Asia, East Europe, etc.
Certificate

Other Firefighting Equipment
FAQ
1. Could you supply the samples?
Free samples always ready if the value is within our purview.
2.Do you have the MOQ?
For conventional products, Low MOQ.
3. Can you add some logo on the products?
Yes. We could OEM and design your logo.
4. Are you able to design or explore a new products for us?
Yes, we are able to, if the clients could supply the drawings or samples.
Send your message to this supplier
People who viewed this also viewed
Find Similar Products By Category
- Supplier Homepage
- Products
- Sprinkler System Alarm Valves
- Wet Alarm Check Valve
- Cast Iron Alarm Valve Pn16 Alarm Check Valve
Related Categories
Hot Searches
More