Product Highlights

  • Compliant with GB Standard: ZSFM/ZSFG type deluge alarm valve based on GB5135.5-2003 standard.
  • Anti-Returning Function: Features lever type structure with anti-returning function for safety.
  • Wide Application Range: Suitable for hospitals, hotels, factories, malls, airports, and libraries.
  • Multiple Connection Sizes: Available in nominal diameters from 50mm to 250mm (2" to 10").
  • Customizable Materials: Material options include Ductile Iron, Cast Iron, and Stainless Steel.
  • Flexible Working Pressure: Rated working pressure is 1.2MPa with high sealing and strength tests.
  • Versatile Activation Methods: Supports electric, wet type, and dry type conduct for pressure release.
  • Durable Construction: Finished with standard red painting or stainless steel for longevity.

Product Images of Automatic Fire Sprinkler System Valve Deluge Valve

Automatic Fire Sprinkler System Valve Deluge Valve pictures & photos
Automatic Fire Sprinkler System Valve Deluge Valve
Automatic Fire Sprinkler System Valve Deluge Valve pictures & photos
Automatic Fire Sprinkler System Valve Deluge Valve
Automatic Fire Sprinkler System Valve Deluge Valve pictures & photos
Automatic Fire Sprinkler System Valve Deluge Valve
Automatic Fire Sprinkler System Valve Deluge Valve pictures & photos
Automatic Fire Sprinkler System Valve Deluge Valve
Automatic Fire Sprinkler System Valve Deluge Valve pictures & photos
Automatic Fire Sprinkler System Valve Deluge Valve
Automatic Fire Sprinkler System Valve Deluge Valve pictures & photos
Automatic Fire Sprinkler System Valve Deluge Valve
  • Automatic Fire Sprinkler System Valve Deluge Valve
    Automatic Fire Sprinkler System Valve Deluge Valve
  • Automatic Fire Sprinkler System Valve Deluge Valve
    Automatic Fire Sprinkler System Valve Deluge Valve
  • Automatic Fire Sprinkler System Valve Deluge Valve
    Automatic Fire Sprinkler System Valve Deluge Valve
  • Automatic Fire Sprinkler System Valve Deluge Valve
    Automatic Fire Sprinkler System Valve Deluge Valve
  • Automatic Fire Sprinkler System Valve Deluge Valve
    Automatic Fire Sprinkler System Valve Deluge Valve
  • Automatic Fire Sprinkler System Valve Deluge Valve
    Automatic Fire Sprinkler System Valve Deluge Valve

Find Similar Products

Product Description

Automatic fire sprinkler system valve deluge valve

Introduction                                                                                    
ZSFM/ZSFG type deluge alarm valve which is based on GB5135.5-2003 standard shows lever type structure and has the anti-returning function. The valve is widely used in open sprinkler system, for instance, deluge system, water curtain system, water mist system. The deluge valve starts when the pressure in the diaphragm is released then the pressure of the water supplying side pushes open the valve clack. To release the pressure in the diaphragm, there are quite some ways,such as electric conduct, wet type conduct, dry type conduct. This type of automatic fire fighting system is suitable for hospitals, hotels, factories, malls, airports, libraries, gym, exhibition center.
 
Technical parameters
Model Rated W.P(Mpa) Sealing Test Pressure(Mpa) Strength Test Pressure(Mpa) Norminal Diameter(mm) Flange Diameter(mm) Symmetric Hole Diameter(mm) Screw Hole No. and Dia ΦA(mm)
ZSFM50 1.2  2.4  4.8 DN50 165 125 4xΦ18
ZSFM65 DN65 185 145 4xΦ18
ZSFM80 DN80 200 160 8xΦ18
ZSFM100 DN100 220 180 8xΦ18
ZSFM125 DN125 220 180 8xΦ18
ZSFM150 DN150 285 240 8xΦ22
ZSFM200 DN200 340 295 12xΦ22
ZSFM250 DN250 405 355 12xΦ26
 
Photoes
Automatic Fire Sprinkler System Valve Deluge Valve
Automatic Fire Sprinkler System Valve Deluge Valve
Automatic Fire Sprinkler System Valve Deluge Valve
Automatic Fire Sprinkler System Valve Deluge Valve

Other Firefighting Equipment
Automatic Fire Sprinkler System Valve Deluge Valve

Certificate
Automatic Fire Sprinkler System Valve Deluge Valve

 

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR247369". Items marked "verified" are certified.

Watch Video
Watch Video
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED
SINCO FIRE AND SECURITY CO., LIMITED

About Our Factory & Business Background

Address
Fuxi Commercial and Business Building, Meilin Street, Quanzhou, Fujian, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DAT, FAS, DDP, DAP, CIP, CPT, Others, FCA
Average Lead Time
Peak Season Lead Time: 1-3 months
Off Season Lead Time: within 15 workdays
Nearest Port
Xiamen, Ningbo, Guangzhou

Our Production Capability & Technical Expertise

Main Products
Fire Hose, Fire Hose Pipe, Water Delivery Hose/Agricultural Hose, Fire Sprinkler Head, Alarm Check Valve, Fire Hydrant, Fire Water Monitor/Water Cannon, Fire Fighting Equipment, Fire Fighting Spray Nozzle, Foam Bladder Tank

Our Industry Experience & Global Business Record

Export Year
2011-03-09
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What standards does the deluge valve comply with?
The ZSFM/ZSFG type deluge alarm valve is based on the GB5135.5-2003 standard.
What are the available nominal diameters?
The valve is available in nominal diameters ranging from 50mm to 250mm, corresponding to 2 inches to 10 inches.
What materials can be customized for this valve?
Customization options for material include Ductile Iron, Cast Iron, and Stainless Steel.
What is the rated working pressure?
The rated working pressure is 1.2MPa, with a sealing test pressure of 2.4MPa and strength test pressure of 4.8MPa.
Where is this fire fighting system suitable for use?
It is suitable for hospitals, hotels, factories, malls, airports, libraries, gyms, and exhibition centers.
How does the deluge valve start?
The valve starts when the pressure in the diaphragm is released, allowing the water supplying side pressure to push open the valve clack.
What are the payment terms accepted?
Accepted payment terms include LC, T/T, D/P, PayPal, Western Union, Small-amount payment, and Money Gram.
What is the lead time for production?
Peak season lead time is 1-3 months, while off-season lead time is within 15 workdays.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now